Slithead to spectrograph: The
   slithead will be designed jointly by JHU and UW to guarantee
   correct optical properties and easy insertion into and removal
   from the spectrograph. UW will fabricate all slitheads, including
   one test unit for fit-checks and optical alignment in
   Baltimore.
   
   UW will be responsible for the slithead
   latch-down control. JHU will design the slithead clamp and door
   mechanism, and supply the clamp and door hardware, but UW will
   supply the control electronics, pneumatic controls, and software.
   Currently, this means that the spectrographs show one air input
   that actuates the JHU-supplied pneumatic clamp and two air inputs
   that control the JHU-supplied actuator for the slithead door
   (open+close motions). Additional control items (sensors, etc.)
   will be designed and installed by JHU if requested.