Документ взят из кэша поисковой машины. Адрес оригинального документа : http://www.atnf.csiro.au/management/atuc/2011oct/docs/ATUC_25Oct2011_DMcC.pdf
Дата изменения: Tue Oct 25 01:35:47 2011
Дата индексирования: Tue Feb 5 11:46:26 2013
Кодировка:

Поисковые слова: universe
Parkes remote operations

David McConnell ATUC 25 Oct 2011
Monday, 24 October 2011 1


History

May 2007: There may also be implications for astronomer access to the telescopes. The level of remote observing possible, the location of observing "control rooms" and operations support staff will all be questioned in the process of setting the new model.

Nov 2007: Projects being planned to address · Automation · Telescope safety · Scheduling · SOC facility

CSIRO. ATUC October 2011

Monday, 24 October 2011

2


History II

May 2008

May 2009 Aims to decrease the amount of manual configuration and monitoring of equipment during and between observing sessions · Manual Control Panel gets more computer control · Increased monitoring and control of focus cabin equipment · Improved computer-controlled rf switching for signal path configuration These measures, necessary for any future model including remote observations, will make current modes of operation more efficient and reliable.

CSIRO. ATUC October 2011

Monday, 24 October 2011

3


Recent progress (projects PDC, PECM)

R · · · ·

ecent progress towards remote operability and diagnosis Telescope Drive System Signal switching matrix Monitoring and control Power synchroniser

CSIRO. ATUC October 2011

Monday, 24 October 2011

4


Recent progress (projects PDC, PECM)

CSIRO. ATUC October 2011

Monday, 24 October 2011

4


Recent progress (projects PDC, PECM)

CSIRO. ATUC October 2011

Monday, 24 October 2011

4


Recent progress (projects PDC, PECM)

Monitor and control

· We now have common monitoring software · ·

(MoniCA) at all ATNF telescopes, including ASKAP In the past 2 years, an additional 1000 points in the Parkes instrumentation are being monitored. Additional computer controls have been added, for example to enable remote starting of the generator.

CSIRO. ATUC October 2011

Monday, 24 October 2011

4


Recent progress (projects PDC, PECM)

Power synchroniser
A power synchroniser has been installed to enable smooth transition from mains to generator power. This greatly reduces interruptions to computer and digital equipment, decreasing downtime and improving reliability.

CSIRO. ATUC October 2011

Monday, 24 October 2011

4


Remote Access to the Parkes Telescope

RAPT
To implement the remaining components in the system to allows remote access to the Parkes Telescope for scientific use.

CSIRO. ATUC October 2011

Monday, 24 October 2011

5


Approach rests on this principle

The safety of the telescope is the responsibility of automated protection systems. The efficient use of the telescope and, by implication, the integrity and quality of the astronomical data, is the responsibility of the operator
.

CSIRO. ATUC October 2011

Monday, 24 October 2011

6


Project Aims

1. To allow safe operation of the telescope with only one person on "close call" but not in the tower. 2.To protect the telescope and its systems automatically. 3.To allow the operator to control the telescope via an internet connection. 4.To allow the operator to receive advice and support from CSIRO staff, not necessarily co-located.

CSIRO. ATUC October 2011

Monday, 24 October 2011

7


What to expect?

· The project will proceed in two threads:
· Design and construction of the Telescope Protection System (TPS)
· Built on elements already in place · Analogous to the Narrabri PMON and to MAPS

· Establish computer interfaces and software for remote observing
· Follow methods used for ATCA and Mopra (VNC) · Run trials as soon as possible and in advance of an operating TPS, with personnel present in the Telescope to guard telescope safety.

CSIRO. ATUC October 2011

Monday, 24 October 2011

8


Project aims (more detail)

1. To allow safe operation of the telescope with only one person on "close-call", but not in the tower. 2. To protect the telescope and its systems automatically: 1. to monitor all critical systems and recognise conditions that threaten the telescope; 2. to place the telescope in a safe state (normally stowed) when appropriate; 3. to notify CASS staff of threats to the telescope and of actions taken; 4. to record all critical monitor and warning data. 3. To allow the operator to control the telescope via an internet connection: 1. to provide the operator with all controls normally needed during standard observations; 2. to provide the operator with the information needed to assess the progress of the observation, with respect to proper operation of telescope systems and data quality; 3. to provide the operator with any information critical to the safety of the telescope. 4. To allow the operator to receive advice and support from CSIRO staff, not necessarily co-located.

CSIRO. ATUC October 2011

Monday, 24 October 2011

9