Next Section:  Introduction
NIMPOL: An imaging polarimeter for the mid-infrared.
Craig H. Smith![]()
  Toby J.T. Moore![]()
  David K. Aitken![]()
  Takuya Fujiyoshi![]()
  
School of Physics, University College, UNSW, Australian Defence Force Academy, Canberra, ACT, 2600, Australia.
c-smith@adfa.oz.au, t-fujiyoshi@adfa.oz.au
current address: Astrophysics Group, School of Electrical  Engineering, Electronics and Physics, Liverpool John Moores University, Byrom St, Liverpool L3 3AF, UK
tjtm@staru1.livjm.ac.uk
current address: Division of Physical Sciences, University of  Hertfordshire, College Lane, Hatfield, HERTS AL10 9AB, UK
D.Aitken@roe.ac.uk
Abstract:
We have built an imaging polarimeter for use at mid-infrared wavelengths (i.e. N band or 8 - 13 
m). The detecting  element is a 128 x 128 element Si:Ga Focal Plane Array, supplied by Amber Engineering, USA.  The polarimeter itself provides diffraction limited images  on a 4-m class telescope and has a field of view of about 32 arcseconds of  sky with 0.25 arcsecond pixels.  We describe the optical design, control electronics, observing modes and detector sensitivities. Also  presented are some observational results to demonstrate the power of this new imaging polarimetric system. 
Keywords: Instrumentation: infrared, polarimetry
 
| HTML Section | Download Full Paper | 
|---|---|