The baseband mixer would go into compression when the a/d
converter got to about 700 counts.
After the change the bbm would start to go into compression when
the a/d was around 1600 counts.
Prior to the change the radars never caused an a/d overflow
(since the mixer could not put out enough power to get to 2048 counts).
After the change the a/d converters would overflow every time a
radar beam would pass by the AO. This was seen in the 1290 radar and
the FAA 1350 MHz radar.
Page 1: 11jun08, .1 second spectra averaged over 1 second.
The Band is centered at 1325 MHz. The 1350 radar is offset 25
MHz from the center of the band.
Top 30 1 second spectra plotted with offsets.
The faa radar points at ao during spectra 11 and 23.
The dashed vertical lines are spaces every 25 MHz from the
center of the band
Bottom: spectra 11 when faa points at AO
Red line: the 1350 radar
Green: the 5th harmonic of the radar (+/-) folded at the
edges.
blue: The 7th harmonic of the radar (+/-) folded at the edges.
Page 2: .01 second spectra averaged over 1 second
The band is centered at 1345 MHz.
Top: 30 1 second averages plotted with offses. The dashed green
line is the center of the band.
Bottom: The 1 second average for spectra 12 when the radar was
strong.
Black line: 1350 radar
green lines: the 5th harmonics
blue lines: the +/- 5 MHz spurs caused by DC.
Page 3: 12jun08. 10 millisecond spectra.
Top: 14 10 millisecond spectra when the faa beam sweeps
by AO.
It saturates for 4 spectra or 40 milliseconds.
The FWHM of the FAA radar is about 40 milliseconds.
The signal probably goes 3 to 6 db above the clipping level.
You also see a birdie at 1340 MHz when the radar isn't
strong. This is the complex image of the 1350 radar (reflected
about the 1345 center).
Bottom: A single 10 millisecond spectra when the radar was
strongest.
The signal is 33 db above the noise floor with a FWHM of 200
KHz
The peak system temperature increase would be this value
divided by the ratio of the Bandwidths, divided by the radar duty
cycle:
(.2/172MHz)*(2800Ipp/5usecsPulse) + 33db= 31db
The A/D converters were set to a 1 sigma rms of 30 counts.
The dynamic range of the A/D is then:
(2047/30)^2 = 37 Db.
This says the A/D has enough dynamic range for this signal....
BUT... We Know the signal strength was compresses so the
31db increase of Tsys is probably low..
Summary:
The change in the a/d voltage range 1.5 V to .78 is causing
overflows in the a/d with the radars.
The radar acts like a sine wave and caused spectral artifacts
when the a/d is clipped.
This has been seen in the faa radar and the 1290 remy radar.
The overflow last for about 40 milliseconds which is equal to the
beam width of the radar.
The overflow must be in the 3 to 6 db range since it goes away
around the fwhm of the radar.
Assuming no compression the measured signal would raise the total
power 31 db. The digitizers set at 30 counts rms should have 37 db
dynamic range. Since we saw the compression the 31 db is low due to the
compression.