Документ взят из кэша поисковой машины. Адрес
оригинального документа
: http://www.naic.edu/~phil/mbeam/ohcals/ohcals_jul04.html
Дата изменения: Wed Aug 11 02:56:55 2004 Дата индексирования: Sat Dec 22 10:33:16 2007 Кодировка: Поисковые слова: mercury program |
sky temp | 5K |
rcvTemp | 8K |
absorber temp | 303K |
scattered ground radiation | 15K |
TsysSky=Tsky+Tscattered+Trcv | 28K |
TsysAbs=Tabs+Trcv | 311K |
The absorber temperature was measured with a thermometer, the scattered
radiation is a value that has been used in other receivers.
The 4 absorber positioning covered the following horns
|
|
|
|
|
|
|
|
|
|
The plots show the results (ps) (pdf) the measurements. The numbering of the plots has board 1 thru board 7 (which is pixel 0 thru 6).
Some comments:
The cal varies by a large amount across the band. If the cal
is being injected at a null in the wave guide then the variation across
the band could come from the changing wavelength. The band covers +/- 3%
in lambda (+/- 10deg in phase). If the distance from the injection point
to the probes is about a meter then this is 1/.18= 5 lambda's. So we might
accumulate 50 degrees of phase across the entire band. Probably not enough
to cause the large variation we see in 20 Mhz.
The probes are not at the same spot so the pattern should be shifted for the two polarizations.
processing: 040729/alfacals.pro