The command REDUCE/CCD can process one or more science frames automatically provided that:
REDUCE/CCD will first identify the Association Table. From this table it gets the names of the input science frames. Next, it will try to find the master calibration frames listed in the table, and will create these if they do not exist yet. After having collected all required calibration data the input frame is checked for its exposure type. Obviously, a dark frame should not be flat fielded and hence the processing options for the dark exposures should be set differently than for the science frames. After having determined the processing options the actual processing starts.