GigaCAM -Figure 2.

GigaCAM Figure 2.

Figure 2.    Measured response of the fully-depleted CCD at ‑100 °C(open circles) for an unoptimized two-layer AR coating (the dark curve through the points is a model calculation).  Response is expected to be significantly higher for optimized AR coatings. For comparison, measured response of the 2k x 4k deep-depletion back-illuminated MIT/Lincoln chip on Keck ESI is shown, as are measurements for two different SITe CCD's on SUBARU and CTIO. Relative spectral responses of standard wide-band filters are shown.