EnvironmentNotConfigured | error | |
The variable SAS_CCFPATH is
not set. | ||
SubTaskFailure | error | |
One of the subtasks that cifbuild
has
invoked failed, and odfcheck
cannot recover from this failure. | ||
UnknownError | error | |
An error was detected but it could not be
determined its origin. | ||
NoMasterCalindexSet | warning | |
odfcheck
tried to run cifbuild
via a Master
Calibration Index File, but no suitable one was found.
corrective action: Run cifbuild without the MIF | ||
AttitudeDiagnosticsFailed | warning | |
odfcheck
detected an error while running the
attitude diagnostics. The exact error is reported.
corrective action: Move on to the next set of tests. | ||
LargeAttitudeExcursions | warning | |
odfcheck
has
detected that the attitude is more than
allowedbadattitudefraction% of the time more than nrms
r.m.s. away from the median.
corrective action: Continue. | ||
TimeCorrelationDiagnosticsFailed | warning | |
odfcheck
detected an error while running the
time correlation diagnostics. The exact error is reported.
corrective action: Move on to the next set of tests. | ||
LargeTimeCorrelationLoss | warning | |
More than
allowedtimecorrelationfraction% of the available data points
had to be discarded in order to reach a good fit of the time
correlation data.
corrective action: Continue. | ||
TelemetryLossDiagnosticsFailed | warning | |
odfcheck
detected an error while running the
telemetry loss diagnostics. The exact error is reported.
corrective action: Move on to the next set of tests. | ||
LargeTelemetryLoss | warning | |
The estimated telemetry loss
was larger than allowedtelemetrylossfraction%.
corrective action: Continue. | ||
EpicCountingModeDiagnosticsFailed | warning | |
odfcheck
detected an error while running the
EPIC counting mode diagnostics. The exact error is reported.
corrective action: Move on to the next set of tests. | ||
EpicCountingModeTimeAnomaly | warning | |
odfcheck
detected an inconsistency in the time
records associated with the CCX data files. Two possible
conditions are detected: the start and end times of the interval when the
instrument is in counting mode are not in the right order,
i.e. the start is later than the end; the duration of the
interval when the instrument is in counting mode is longer than
the exposure duration. Details are given in the message attached
to the warning.
corrective action: Continue with the current test. | ||
PnMinimumEnergyDiagnosticsFailed | warning | |
odfcheck
detected an error while running the
PN minimum energy diagnostics. The exact error is reported.
corrective action: Move on to the next set of tests. | ||
UnknownError | warning | |
An error
was detected but it could not be determined its origin.
corrective action: Move on to the next set of tests. | ||
OMPAXIterations | warning | |
odfcheck
detected that more than 4 iterations were
reported for the OM priority field acquisition.
corrective action: Continue with the current test. | ||
OMPAXGuideStars | warning | |
odfcheck
detected an inconsistency in the number of
uploaded and found guide stars. Details are reported.
corrective action: Continue with the current test. | ||
OMPAXDiagnosticsFailed | warning | |
odfcheck
detected an error while running the OM
priority field acquisition diagnostics. The exact error is
reported.
corrective action: Move on to the next set of tests. | ||
HousekeepingDiagnosticsFailed | warning | |
odfcheck
detected an error while running the
housekeeping diagnostics. The exact error is reported.
corrective action: Move on to the next set of tests. | ||
HkgtigenFailed | warning | |
odfcheck
detected an error while running
hkgtigen. The exact error is reported.
corrective action: Continue with the current test. | ||
MosTemperatureDiagnosticsFailed | warning | |
odfcheck
found that one EMOS exposure had a mean
temperature lower than the threshold. The exposure number is reported.
corrective action: Continue with the current test. | ||
PnEnergyDiagnosticsFailed | warning | |
odfcheck
found one or more PN science files with an
incorrect energy value. The exposure number is reported.
corrective action: Continue with the current test. | ||
SasComplianceDiagnosticsFailed | warning | |
odfcheck
detected an error while running the SAS
compliance diagnostics. The exact error is reported.
corrective action: Move on to the next set of tests. |