Errors XMM-Newton SAS Home Page
XMM-Newton Science Analysis System


odfcheck (odfcheck-0.18.2) [xmmsas_20050815_1803-6.5.0]

Parameters Home Page Input Files Home Index

Meta Index / Home Page

Errors

This section documents warnings and errors generated by this task (if any). Note that warnings and errors can also be generated in the SAS infrastructure libraries, in which case they would not be documented here. Refer to the index of all errors and warnings available in the HTML version of the SAS documentation.

EnvironmentNotConfigurederror 
 The variable SAS_CCFPATH is not set.
 
SubTaskFailureerror 
 One of the subtasks that cifbuild has invoked failed, and odfcheck cannot recover from this failure.
 
UnknownErrorerror 
 An error was detected but it could not be determined its origin.
 
NoMasterCalindexSetwarning 
 odfcheck tried to run cifbuild via a Master Calibration Index File, but no suitable one was found.
corrective action: Run cifbuild without the MIF
 
AttitudeDiagnosticsFailedwarning 
 odfcheck detected an error while running the attitude diagnostics. The exact error is reported.
corrective action: Move on to the next set of tests.
 
LargeAttitudeExcursionswarning 
 odfcheck has detected that the attitude is more than allowedbadattitudefraction% of the time more than nrms r.m.s. away from the median.
corrective action: Continue.
 
TimeCorrelationDiagnosticsFailedwarning 
 odfcheck detected an error while running the time correlation diagnostics. The exact error is reported.
corrective action: Move on to the next set of tests.
 
LargeTimeCorrelationLosswarning 
 More than allowedtimecorrelationfraction% of the available data points had to be discarded in order to reach a good fit of the time correlation data.
corrective action: Continue.
 
TelemetryLossDiagnosticsFailedwarning 
 odfcheck detected an error while running the telemetry loss diagnostics. The exact error is reported.
corrective action: Move on to the next set of tests.
 
LargeTelemetryLosswarning 
 The estimated telemetry loss was larger than allowedtelemetrylossfraction%.
corrective action: Continue.
 
EpicCountingModeDiagnosticsFailedwarning 
 odfcheck detected an error while running the EPIC counting mode diagnostics. The exact error is reported.
corrective action: Move on to the next set of tests.
 
EpicCountingModeTimeAnomalywarning 
 odfcheck detected an inconsistency in the time records associated with the CCX data files. Two possible conditions are detected: the start and end times of the interval when the instrument is in counting mode are not in the right order, i.e. the start is later than the end; the duration of the interval when the instrument is in counting mode is longer than the exposure duration. Details are given in the message attached to the warning.
corrective action: Continue with the current test.
 
PnMinimumEnergyDiagnosticsFailedwarning 
 odfcheck detected an error while running the PN minimum energy diagnostics. The exact error is reported.
corrective action: Move on to the next set of tests.
 
UnknownErrorwarning 
 An error was detected but it could not be determined its origin.
corrective action: Move on to the next set of tests.
 
OMPAXIterationswarning 
 odfcheck detected that more than 4 iterations were reported for the OM priority field acquisition.
corrective action: Continue with the current test.
 
OMPAXGuideStarswarning 
 odfcheck detected an inconsistency in the number of uploaded and found guide stars. Details are reported.
corrective action: Continue with the current test.
 
OMPAXDiagnosticsFailedwarning 
 odfcheck detected an error while running the OM priority field acquisition diagnostics. The exact error is reported.
corrective action: Move on to the next set of tests.
 
HousekeepingDiagnosticsFailedwarning 
 odfcheck detected an error while running the housekeeping diagnostics. The exact error is reported.
corrective action: Move on to the next set of tests.
 
HkgtigenFailedwarning 
 odfcheck detected an error while running hkgtigen. The exact error is reported.
corrective action: Continue with the current test.
 
MosTemperatureDiagnosticsFailedwarning 
 odfcheck found that one EMOS exposure had a mean temperature lower than the threshold. The exposure number is reported.
corrective action: Continue with the current test.
 
PnEnergyDiagnosticsFailedwarning 
 odfcheck found one or more PN science files with an incorrect energy value. The exposure number is reported.
corrective action: Continue with the current test.
 
SasComplianceDiagnosticsFailedwarning 
 odfcheck detected an error while running the SAS compliance diagnostics. The exact error is reported.
corrective action: Move on to the next set of tests.
 