Документ взят из кэша поисковой машины. Адрес оригинального документа : http://xmm.vilspa.esa.es/sas/8.0.0/watchout/5.3/PSF.shtml
Дата изменения: Unknown
Дата индексирования: Fri Sep 5 18:36:34 2008
Кодировка:
XMM-Newton SAS: Watchout Page RGS spectrum of HR1099
Home Watchouts Software requirements Installation Download Documentation Calibration Help

LOW, MEDIUM, HIGH, EXTENDED ... how do I get "the" EPIC PSF from calview?

The calibration file GUI task calview supports the visualization of the four basic representations of the X-ray Point Spread Function (PSF) that are encoded in the Calibration Access Layer (CAL) as part of the SAS. They can be selected by setting the Accuracy Level parameter in the calview window before invoking View/PSF or View/Encircled Energy/Encircled Energy (PSF): As a baseline, the EXTENDED mode gives the best results for 1-D PSFs. A summary of its applicability is given in the EPIC Calibration Status Document. There is no good general model for a 2-D PSF yet, due principally to the lack of the necessary in-orbit measurements. The MEDIUM model, although based on simulations, and although it assumes that all the mirror modules have the same response, may at least give an idea of the off-axis PSF deformation. For more detailed information on the LOW, MEDIUM and HIGH mode PSFs, as well as the calibration files and the calibration SAS interface, the user is referred to the Calibration Access and Data Handbook.


Pages maintained by SAS librarian.
Any question about SAS should be addressed to the XMM-Newton help desk.