Документ взят из кэша поисковой машины. Адрес оригинального документа : http://zebu.uoregon.edu/~uochep/talks/talks06/sinev2-10-06.pdf
Дата изменения: Thu Dec 7 23:35:31 2006
Дата индексирования: Tue Oct 2 11:51:47 2012
Кодировка:

Поисковые слова: ьфб лймс
Tracking resolution
Nick Sinev, University of Oregon


Software tools
· Fitter ­ SLD type weight matrix based.
­ Gives covariance Matrix for fitted track ­ Can calculate covariance Matrix without hits ­ simulate hits itself and use only detector geometry description (compact.xml file)

· Hits smearing
­ First combine hits (SimTrackerHit) from the same particle in the detector layer (there may be few of them because Geant generates many hits along track) ­ Smear resulting TrackerHit and assign measurement matrix to it according to given detectors resolutions
10/26/2006 Nick Sinev, Tracking resolution 2


SiD00 detector

10/26/2006

Nick Sinev, Tracking resolution

3


Momentum measurements- Pt resolution vs full momentum of the track

Comparison of Fast (magenta) and full MC for SiD detector for Tan() = 0.3
10/26/2006 Nick Sinev, Tracking resolution 4


Momentum measurements- Pt resolution vs full momentum of the track

Comparison of Fast (red) and full MC for SiD detector for Tan() = 2.8
10/26/2006 Nick Sinev, Tracking resolution 5


Momentum measurements-1 Gev

Very low momentum tracks Pt resolution vs Tan() in Fast MC (black), SiD00 (green) and SiDMay06 (magenta).
10/26/2006 Nick Sinev, Tracking resolution 6


Momentum measurements-100 Gev

High momentum tracks Pt resolution vs Tan() in Fast MC (red), SiD00 (black) and SiDMay06 (magenta). Why such large difference with Fast MC? Does Fast MC include sensors resolution?
10/26/2006 Nick Sinev, Tracking resolution 7


Impact parameter D0 resolution vs momentum

Fast MC ­ blue, full MC ­ red. Tan() = 0.3 (exactly for full MC and average for Fast 10/26/2006 MC). Nick Sinev, Tracking resolution

8


Impact parameter D0 resolution vs momentum

Tan () = 3.5 Fast MC (magenta), full MC SiD00 ­ blue, SiDMay06 - green
10/26/2006 Nick Sinev, Tracking resolution 9


Impact parameter Z0 resolution

·

Tan()=0.3 Fast MC (red) full MC, SiD00 ­blue. What is the reason for bad Fast MC resolution at high momentum?
Nick Sinev, Tracking resolution 10

10/26/2006


Impact parameter Z0 resolution

·

Tan()=3.5 Fast MC ­green, full MC, SiD00 ­yellow, full MC, SiDMay06- blue.
Nick Sinev, Tracking resolution 11

10/26/2006


Impact parameter Z0 resolution

·

1 GeV full momentum. Fast MC ­cyan, full MC, SiD00 ­red, full MC, SiDMay06- blue.
Nick Sinev, Tracking resolution 12

10/26/2006


Conclusions
· We have tool which allows to study effects of detector design on tracking resolutions with full detector simulation, but without running Geant. Geometry description in the form of xml file is enough. · I hope Kalman fitter can do even better job. I still not completely satisfied with weight matrix fitter performance at low momentum (overestimates resolution by few %) and in ec region ­ underestimates (by 5-8%) resolution. I am eager to compare it with Kalman fitter.
10/26/2006 Nick Sinev, Tracking resolution 13