361. General calibration
... Next: Hysteresis calibrationЮ Up: Server configuration Previous: Server configuration Contents Index . Calibration data are transferred to each client on connection. It allow user to set correct scanning parameters. ... If sensivity is set, for example, as and graphite lattice period obtained in calibration measurements is equal to , and from tabulated data it is then correct sensitivity value can be found using this equation . ... Hysteresis - Path to hysteresis calibration file (see 2.1.2 ). ...
[
Сохраненная копия
]
Ссылки http://www.spm.genebee.msu.ru/manual/en/node27.html -- 6.4 Кб -- 04.02.2005
Похожие документы
Похожие документы
362. Hysteresis calibrationЮ
... Next: STM Calibration Up: Server configuration Previous: General calibration Contents Index . To correct non-linear distortions in sizes of the sample and objects on it, that arise due to piezoceramics hysteresis, a calibration file is used. ... If you have a calibration file, you can use it by selecting Calibration tab and enter a path to it in a field that appear. ... Next: STM Calibration Up: Server configuration Previous: General calibration Contents Index Filonov 2005-02-04 ...
[
Сохраненная копия
]
Ссылки http://www.spm.genebee.msu.ru/manual/en/node28.html -- 4.9 Кб -- 04.02.2005
Похожие документы
Похожие документы
363. STM Calibration
... STM Cal. tab allow user to adjust calibration data for tunneling mode of SPM operation. ... With positive feedback incriase in error signal leads to increase in feedback signal, with negative feedback - increase in error signal leads to decrease in feedback signal. In STM mode positive feedback is used. ... At the present moment 0 channel is used for error (deflection) signal, and 1-st channel used for RMS signal (which is used as feedback signal in Resonance AFM mode) . ...
[
Сохраненная копия
]
Ссылки http://www.spm.genebee.msu.ru/manual/en/node29.html -- 5.7 Кб -- 04.02.2005
Похожие документы
Похожие документы
364. AFM calibration
... Next: Resonance AFM calibration Up: Server configuration Previous: STM Calibration Contents Index . AFM Cal. tab allow user to adjust calibration data for atomic-force microscope mode of SPM operation. Max Deflection, nm - maximum value of cantilever deflection. Spring Constant, N/m - cantilever spring constant. ... In the AFM mode of operation feedback is positive. ... Next: Resonance AFM calibration Up: Server configuration Previous: STM Calibration Contents Index Filonov 2005-02-04 ...
[
Сохраненная копия
]
Ссылки http://www.spm.genebee.msu.ru/manual/en/node30.html -- 5.0 Кб -- 04.02.2005
Похожие документы
Похожие документы
365. Resonance AFM calibration
... Next: COM-port calibration Up: Server configuration Previous: AFM calibration Contents Index . Resonance AFM Cal. tab allow user to adjust calibration data for resonance atomic-force microscope mode of SPM operation. Max Deflection, mл - maximum value of cantilever deflection amplitude. ... Max Zmod Frequency, Hz - calibrated maximum frequency of for amplitude modulation of cantilever oscillations. Inverse feedback - see 2.1.2 . ... Inverse deflection - error signal sign. ...
[
Сохраненная копия
]
Ссылки http://www.spm.genebee.msu.ru/manual/en/node31.html -- 5.3 Кб -- 04.02.2005
Похожие документы
Похожие документы
366. COM-port calibration
... Next: Network configuration Up: Server configuration Previous: Resonance AFM calibration Contents Index . Aux cal. tab allow user to adjust calibration data and parameters for additional data channel for the data that came trough COM port. Auxiliary port enabled - Flag that turns additional data channel on. ... Max AUX port data - Maximum value for data that is receiving. ... COM port number - number of the COM-port. ... Initialization file path - Path to initialization file. ...
[
Сохраненная копия
]
Ссылки http://www.spm.genebee.msu.ru/manual/en/node32.html -- 5.3 Кб -- 04.02.2005
Похожие документы
Похожие документы
367. Network configuration
... Next: HTTP server configuration Up: Server configuration Previous: COM-port calibration Contents Index . Network tab allow to configure following properties: . Listen IP - IP-address, on which server is waiting for client connection. ... Max. ... Buffer Size, Kb - When any client's buffer reach this size this client receive shorter amount of data (client doesn't recive image data) . ... When client's buffer size exceed this value, server disconnect that client automatically. ...
[
Сохраненная копия
]
Ссылки http://www.spm.genebee.msu.ru/manual/en/node33.html -- 5.2 Кб -- 04.02.2005
Похожие документы
Похожие документы
368. HTTP server configuration
... Next: DAC numbers Up: Server configuration Previous: Network configuration Contents Index . Enable WWW server - enabling WWW server. With WWW server enabled current images would be accessible through Internet. ... Listen IP - IP-address, on which server is waiting for client connection. ... Listen port - port which is used for web browsers connection. ... Next: DAC numbers Up: Server configuration Previous: Network configuration Contents Index Filonov 2005-02-04 ...
[
Сохраненная копия
]
Ссылки http://www.spm.genebee.msu.ru/manual/en/node34.html -- 5.1 Кб -- 04.02.2005
Похожие документы
Похожие документы
369. DAC numbers
Russian . Next: High resolution DACs numbers Up: Server configuration Previous: HTTP server configuration Contents Index . A tab labeled DACs allow to configure addresses of DACs, that are responsible for: piezomanipulator movement coordinates, tunneling gap voltage, stepper motor control, modulation frequency in RAFM mode and sample temperature control. Russian . Next: High resolution DACs numbers Up: Server configuration Previous: HTTP server configuration Contents Index Filonov 2005-02-04
[
Сохраненная копия
]
Ссылки http://www.spm.genebee.msu.ru/manual/en/node35.html -- 4.7 Кб -- 04.02.2005
Похожие документы
Похожие документы
370. High resolution DACs numbers
... Next: Sample landing preferences Up: Server configuration Previous: DAC numbers Contents Index . ... DACs addresses of DACs, that responsible for high resolution data obtaining from X, Y, Z coordinates of piezomanipulator, can be configured. Values in field Gain show their amplification coefficients (compare to 2.1.2 ). ... Next: Sample landing preferences Up: Server configuration Previous: DAC numbers Contents Index Filonov 2005-02-04 ...
[
Сохраненная копия
]
Ссылки http://www.spm.genebee.msu.ru/manual/en/node36.html -- 4.9 Кб -- 04.02.2005
Похожие документы
Похожие документы
371. Sample landing preferences
... Next: Stepper motor configuration Up: Server configuration Previous: High resolution DACs numbers Contents Index . ... Landing It - tunneling current value (in % from that was set as bearing value for scanning) that if reached stop the tip to sample landing process. Landing delay - number of delay cycles corresponding to singe motor step during ordinary (started by client) landing process. ... During landing process before every step piezomanipulator fully retract the sample. ...
[
Сохраненная копия
]
Ссылки http://www.spm.genebee.msu.ru/manual/en/node37.html -- 5.9 Кб -- 04.02.2005
Похожие документы
Похожие документы
372. Stepper motor configuration
... Next: Additional data acquiring channels Up: Server configuration Previous: Sample landing preferences Contents Index . Forward value - a value that sets forward direction of stepper motor movement. ... Enable "Power On/Off" - this field allow to enable control of stepper motor power supply. ... If user activate stepper motor movement the power supply will turn on automatically. On"/"Off" value - values that sets corresponding power supply status of the stepper motor. ...
[
Сохраненная копия
]
Ссылки http://www.spm.genebee.msu.ru/manual/en/node38.html -- 5.3 Кб -- 04.02.2005
Похожие документы
Похожие документы
373. Additional data acquiring channels
Russian . Next: DSP Timing Up: Server configuration Previous: Stepper motor configuration Contents Index . Using Channels tab user can configure bits of the stepper motor DAC that is used to switch commutators which pass signals to ADC. Russian . Next: DSP Timing Up: Server configuration Previous: Stepper motor configuration Contents Index Filonov 2005-02-04
[
Сохраненная копия
]
Ссылки http://www.spm.genebee.msu.ru/manual/en/node39.html -- 4.6 Кб -- 04.02.2005
Похожие документы
Похожие документы
374. DSP Timing
Russian . Next: Events logging Up: Server configuration Previous: Additional data acquiring channels Contents Index . On the DSP Timing tab DSP and microscope's electronic main working frequencies can be configured. It is strongly recommended not to change them. Russian . Next: Events logging Up: Server configuration Previous: Additional data acquiring channels Contents Index Filonov 2005-02-04
[
Сохраненная копия
]
Ссылки http://www.spm.genebee.msu.ru/manual/en/node40.html -- 4.6 Кб -- 04.02.2005
Похожие документы
Похожие документы
375. Events logging
... Next: Driver configuration Up: Server configuration Previous: DSP Timing Contents Index . With Logging tab user can configure logging options for events and errors. It is possible to turn off logging, change save path for log files, and log file names. It is possible to put special symbols inside the names, that will be changed to current month, year and day: . ... short name of a day . ... number of a week in a year, with Sunday as a first day in a week (00 - 53). %w . ...
[
Сохраненная копия
]
Ссылки http://www.spm.genebee.msu.ru/manual/en/node41.html -- 5.4 Кб -- 04.02.2005
Похожие документы
Похожие документы
376. Driver configuration
Russian . Next: Client Up: Server configuration Previous: Events logging Contents Index . On a Driver tab DSP interrupt and I/O ports addresses can be configured. User can change this values if he had an administrator privileges. Otherwise these fields wouldn't be accessible for editing. The parameters configured should correspond to the values set on the DSP board by jumpers. Russian . Next: Client Up: Server configuration Previous: Events logging Contents Index Filonov 2005-02-04
[
Сохраненная копия
]
Ссылки http://www.spm.genebee.msu.ru/manual/en/node42.html -- 4.6 Кб -- 04.02.2005
Похожие документы
Похожие документы
377. Client
... Next: Connection to a Server Up: SPM Control Previous: Driver configuration Contents Index . In the client part of the '' FemtoScan `` software package ('' FemtoScan `` program, file femtoscan.exe) all scanning parameters can be configured. All commands that control scan process, sample landing/retracting are come from the client program. ... Plane tab . It(Z) tab (STM mode), F(Z) tab (AFM mode), D(Z) tab (RAFM mode). It(Ut) tab (STM mode) . Tuning tab (RAFM mode) . ...
[
Сохраненная копия
]
Ссылки http://www.spm.genebee.msu.ru/manual/en/node43.html -- 7.6 Кб -- 04.02.2005
Похожие документы
Похожие документы
378. Connection to a Server
... To connect to a server select command Connect as Master (button ) or Connect as Client (button ) in SPM menu. ... Figure 2.2: Connecting to a server in client mode. Connection window. ... In this window you should enter the address you connected to and enter some additional data. ... If you try to connect as a Master to the server which already has somebody connected as a Master, you will be connected as a Client. In case you successfully connected as a Master both buttons will be drowned. ...
[
Сохраненная копия
]
Ссылки http://www.spm.genebee.msu.ru/manual/en/node44.html -- 7.9 Кб -- 04.02.2005
Похожие документы
Похожие документы
379. Scan parameters
... Next: Plane tab Up: Client Previous: Connection to a Server Contents Index . Figure 2.4: Scan parameters. STM mode of operation. ... AFM mode of operation. ... All scan parameters can be configures in Parameters window (pic. ... Client part of `` FemtoScan '' software allows to control microscope operating in three different scanning modes - tunneling mode(STM), atomic-force mode (AFM) and resonance atomic-force (RAFM). ... It(Z) tab (STM mode), F(Z) tab (AFM mode), D(Z) tab (RAFM mode). ...
[
Сохраненная копия
]
Ссылки http://www.spm.genebee.msu.ru/manual/en/node45.html -- 10.0 Кб -- 04.02.2005
Похожие документы
Похожие документы
380. Plane tab
... Next: It(Z) tab (STM mode), Up: Scan parameters Previous: Scan parameters Contents Index . On this tab user can set scan parameters corresponding to surface scanning Z(X,Y). ... Scanning mode can be set using falling list that is in upper part of the tab window . ... Steps/lines -- number of points in a scan line and number of lines in surface image. ... On the Litography tab user can choose Mask image , litography mode and parameters for probe-sample interaction during lithography process. ...
[
Сохраненная копия
]
Ссылки http://www.spm.genebee.msu.ru/manual/en/node46.html -- 12.5 Кб -- 04.02.2005